@@ -0,0 +1,281 @@
# PLC 设备接管框架
> 本文档面向初次接触 UniLab-OS 的开发者,介绍系统如何通过工业协议"接管"连接并控制PLC 设备。
## 什么是"PLC 接管"
**PLC**可编程逻辑控制器是工厂设备的控制核心驱动机械臂、泵、阀门等硬件。UniLab-OS 通过网络协议直接读写 PLC 内部变量,从而控制设备运行:
```
UniLab-OSPython ←通信协议→ PLC ←电信号→ 电机/气缸/传感器
```
UniLab-OS 提供两套接管框架,对应两种工业协议:
| 框架 | 协议 | 应用项目 | 核心文件 |
| --------------- | ---------------- | ------------------ | ----------------------------------------------------------- |
| **Modbus 框架** | Modbus TCP / RTU | 扣式电池装配工站 | `unilabos/device_comms/modbus_plc/client.py` |
| **OPC UA 框架** | OPC UA | 后处理工站(怀柔) | `unilabos/devices/workstation/post_process/post_process.py` |
两套框架**设计思想完全一致**,底层通信协议不同。理解一个,另一个基本触类旁通。
---
## 核心概念
### 节点Node
节点是 PLC 内部一个具体的变量地址,可以理解为 PLC 的一个输入/输出端口。
| 属性 | 说明 | 示例 |
| ---- | -------------------------------------- | -------------------- |
| 名称 | 人类可读标识 | `COIL_SYS_START_CMD` |
| 地址 | PLC 内存地址 | `0x0064` |
| 类型 | Coil / HoldRegister / InputRegister 等 | `coil` |
```
PLC 内存空间
├── Coil 区: True / False ← 控制开关量(启动/停止/复位)
├── Hold Reg: 120, 35.5 … ← 存参数值(速度、位置)
└── Input Reg: 99.8, 42 … ← 只读传感器数据
```
### 动作生命周期Action Lifecycle
每个设备动作被拆分为 4 个阶段,用 `try/finally` 保证安全性:
```python
try:
init(...) # 写入参数(速度、位置等)— 可选
start(...) # 发触发信号 + 轮询等待完成
stop(...) # 复位触发信号(成功时执行)
except:
is_err = True
finally:
cleanup(...) # 无论成败都执行,作为安全兜底
```
| 阶段 | 何时执行 | 典型内容 |
| --------- | ----------------------- | ------------------------------------ |
| `init` | 成功路径(可选) | 写运动速度 = 20.0 |
| `start` | 成功路径 | 写启动位 = True等待完成位 = True |
| `stop` | 成功路径 | 写启动位 = False正常复位 |
| `cleanup` | **无论成败**finally | 安全兜底复位,防止异常时设备持续运动 |
> **为什么 `cleanup` 无论成败都执行?**
> 若 `start` 阶段因传感器故障抛出异常,`stop` 会被跳过PLC 触发位仍为 `True`——设备可能持续运动。`cleanup` 放在 `finally` 块中,作为最后的安全保障,确保 PLC 一定被复位到安全状态。实际上大多数动作将 `cleanup` 设为 `null`,由 `stop` 负责正常复位即可。
---
## Modbus 框架
**核心文件**`unilabos/device_comms/modbus_plc/client.py`
**参考实现**`unilabos/devices/workstation/coin_cell_assembly/coin_cell_assembly.py`
### 连接与节点注册
```python
from unilabos.device_comms.modbus_plc.client import TCPClient, BaseClient
# 1. 建立 TCP 连接
client = TCPClient(addr="172.16.28.102", port=502)
client.client.connect()
# 2. 从 CSV 加载节点定义
nodes = BaseClient.load_csv("coin_cell_assembly_b.csv")
# 3. 注册节点,之后可按名称访问
client.register_node_list(nodes)
# 访问节点
client.use_node('COIL_SYS_START_CMD').write(True)
value, err = client.use_node('COIL_SYS_START_STATUS').read(1)
```
**CSV 格式**`Name` / `DeviceType` / `Address` / `DataType`
| Name | DeviceType | Address | DataType |
| ------------------ | ------------- | ------- | -------- |
| COIL_SYS_START_CMD | coil | 100 | INT16 |
| REG_SPEED | hold_register | 200 | FLOAT32 |
### 三段式接管流程(扣式电池工站)
PLC 设备通常需要按固定顺序切换模式,以扣式电池工站为例:
```
Python PLC
│── 写 HAND_CMD = True ─────────>│ 切换到手动模式
│<─ 读 HAND_STATUS = True ────────│ 确认进入手动
│── 写 INIT_CMD = True ──────────>│ 执行初始化
│<─ 读 INIT_STATUS = True ─────────│ 初始化完成
│── 写 HAND_CMD = False ──────────>│ 复位(脉冲信号)
│── 写 INIT_CMD = False ──────────>│ 复位
│── 写 AUTO_CMD = True ───────────>│ 切换自动模式
│<─ 读 AUTO_STATUS = True ─────────│ 自动模式就绪
│── 写 AUTO_CMD = False ──────────>│ 复位
│── 写 START_CMD = True ──────────>│ 开始运行
│<─ 读 START_STATUS = True ────────│ 运行确认
│── 写 START_CMD = False ──────────>│ 复位
```
> **脉冲信号模式**:命令写 `True` → 等待 PLC 状态位确认 → 命令写回 `False`,这是大多数 PLC 的标准触发方式,而不是保持高电平。
### JSON 配置方式
Modbus 框架支持纯 JSON 配置,无需手写 Python 流程:
```json
{
"register_node_list_from_csv_path": {"path": "M01.csv"},
"create_flow": [
{
"name": "归位",
"action": [{
"address_function_to_create": [
{"func_name": "pos_tip", "node_name": "M01_idlepos_coil_w", "mode": "write", "value": true},
{"func_name": "pos_tip_read", "node_name": "M01_idlepos_coil_r", "mode": "read", "value": 1},
{"func_name": "manual_stop", "node_name": "M01_manual_stop_coil_r","mode": "read", "value": 1}
],
"create_init_function": {"func_name": "idel_init", "node_name": "M01_idlepos_velocity_rw", "mode": "write", "value": 20.0},
"create_start_function": {
"func_name": "idel_position",
"write_functions": ["pos_tip"],
"condition_functions": ["pos_tip_read", "manual_stop"],
"stop_condition_expression": "pos_tip_read[0] and manual_stop[0]"
},
"create_stop_function": {"func_name": "idel_stop", "node_name": "M01_idlepos_coil_w", "mode": "write", "value": false},
"create_cleanup_function": null
}]
}
],
"execute_flow": ["归位"]
}
```
执行:
```python
client.execute_procedure_from_json(json_data)
```
---
## OPC UA 框架
**核心文件**`unilabos/devices/workstation/post_process/post_process.py`
**参考实现**`unilabos/devices/workstation/post_process/opcua_huairou.json`
### 与 Modbus 的主要区别
| 特性 | Modbus | OPC UA |
| ---------- | -------------------- | --------------------------------- |
| 节点发现 | 手动填写 CSV 地址 | **自动遍历**服务器节点树 |
| 数据获取 | 轮询(主动问) | **订阅推送**(有变化时通知) |
| 节点标识 | 数字地址(如 `100` | 字符串 NodeId`ns=2;s=速度` |
| 断线处理 | 无 | **后台监控线程**自动重连 |
| 认证安全 | 无 | 支持用户名/密码 |
| 工作流调用 | 手动调用 | **自动注册为实例方法** |
### 连接与节点发现
```python
from unilabos.devices.workstation.post_process.post_process import OpcUaClient
client = OpcUaClient(
url="opc.tcp://192.168.1.100:4840",
username="admin", # 可选
password="123456", # 可选
config_path="opcua_huairou.json", # 自动加载工作流配置
cache_timeout=5.0, # 节点值缓存 5 秒
subscription_interval=500, # 每 500ms 接收推送
)
# 节点自动通过订阅保持最新值,读取直接查本地缓存
value = client.get_node_value("grab_complete")
```
### JSON 配置方式
```json
{
"register_node_list_from_csv_path": {"path": "opcua_nodes_huairou.csv"},
"create_flow": [
{
"name": "trigger_grab_action",
"description": "触发反应罐及原料罐抓取动作",
"parameters": ["reaction_tank_number", "raw_tank_number"],
"action": [{
"init_function": {
"func_name": "init_grab_params",
"write_nodes": ["reaction_tank_number", "raw_tank_number"]
},
"start_function": {
"func_name": "start_grab",
"write_nodes": {"grab_trigger": true},
"condition_nodes": ["grab_complete"],
"stop_condition_expression": "grab_complete == True",
"timeout_seconds": 999999.0
},
"stop_function": {
"func_name": "stop_grab",
"write_nodes": {"grab_trigger": false}
}
}]
}
]
}
```
配置加载后,工作流自动注册为实例方法:
```python
# 直接调用,传入参数,框架自动写入对应节点
client.trigger_grab_action(reaction_tank_number=2, raw_tank_number=3)
```
---
## 新增设备快速上手
### 使用 Modbus 框架
```
1. 从 PLC 工程师处拿到地址表,按格式填写 CSVName/DeviceType/Address/DataType
2. 继承 BaseClient在 __init__ 中连接并注册节点
3. 参考 coin_cell_assembly.py 编写三段式接管函数(手动→初始化→自动→启动)
4. 或直接编写 JSON 配置,调用 execute_procedure_from_json()
```
### 使用 OPC UA 框架
```
1. 确认设备支持 OPC UA拿到服务器 URL格式opc.tcp://IP:PORT
2. 准备 CSV 节点定义文件(可选,也可让框架自动发现)
3. 编写 JSON 配置:定义 parameters、init/start/stop 函数
4. 实例化 OpcUaClient传入 config_path直接调用自动注册的工作流方法
```
---
## 常见问题
**Q: `node {name} is not registered` 报错?**
A: 节点名不在 CSV 或未调用 `register_node_list_from_csv_path()`
**Q: 程序卡死在 `while not status(): sleep(1)`**
A: PLC 未返回预期完成信号。检查PLC 是否在正确运行模式、状态位地址是否正确、PLC 有无报警。
**Q: OPC UA 连接成功但读不到节点?**
A: 检查节点名称是否与服务器显示名一致(区分中英文)。可调用 `_find_nodes()` 打印服务器全部节点。
**Q: 应该选 Modbus 还是 OPC UA**
A: 取决于设备支持的协议,由 PLC 工程师决定。OPC UA 功能更完整,条件允许优先选择。
---